(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Adhezion Biomedical SP-015V50 - Secureportiv Catheter Securement Adhesive, 50/Box

Adhezion Biomedical # SP-015V50 - Secureportiv Catheter Securement Adhesive, 50/Box
Part Number Adhezion Biomedical SP-015V50
SKU Number CIA7015101
Sell Unit BOX
Ships Within 3-5 Days
List Price $912.50
Enter a valid quantity
Product Description

Adhezion Biomedical SP-015V50 - Secureportiv Catheter Securement Adhesive, 50/Box

Adhezion Biomedical SP-015V50 Secureportiv Catheter Securement Adhesive

The most versatile care and maintenance device in vascular access

SecurePortIV adhesive is improving vascular access outcomes by delivering enhanced securement, sealing the insertion site, and providing microbial protection.

Intravenous catheter insertion is the most common invasive hospital procedure performed worldwide, but its extremely prone to complications, with an overall failure rate that has been estimated at 8% to 43% depending on device type.

But with SecurePortIV, all that is changing.

SecurePortIV is the first and only cyanoacrylate adhesive that is FDA-cleared for securement of vascular access devices. It is simple, safe and effective for all patient populations and devices. Other benefits include:

3X stronger and infinitely simpler securement than transparent film dressings alone and superior adhesiveness compared with mechanical securement devices.

  • Reduces catheter movement, migration, and dislodgement

Effectively seals the catheter insertion site

  • Can help reduce early dressing changes and eliminate 24-48 hour initial dressing change protocols

Unique defense against catheter-related bloodstream infections

  • Immobilizes skin flora that has not been removed by standard skin prep
  • Formulation reported to exhibit activity against gram-negative and gram-positive bacteria, yeast, and fungi eliminating greater than 8-logs after 3 minutes of contact in in-vitro studies
  • Reduces the risk of CLABSI
SecurePortIV adhesive can be used on peripheral IVs by placing it over the insertion site and underneath the catheter hub.SecurePortIV adhesive can be used on central lines by placing it over the insertion site and/or anywhere along the exposed portion of the catheter.

Key Benefits of Using Tissue Adhesive for IV Catheters

Reduced insertion site bleeding and oozing80%
Reduced dressing changes45% - 57%
Reduced migration and dislodgement93%
Reduced risk for CLABSI50% - 93%
Related Products