(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

B Braun 473036 - 0.2 Micron Low Volume IV Filter Ensuring Safe and Efficient Intravenous Therapy50/CS

B Braun # 473036 - 0.2 Micron Low Volume IV Filter  Ensuring Safe and Efficient Intravenous Therapy50/CS
Part Number B Braun 473036
SKU Number CIA7031278
Sell Unit CASE
Ships Within 3-5 Days
List Price $314.50
Enter a valid quantity
Product Description

B Braun 473036 - 0.2 Micron Low Volume IV Filter Ensuring Safe and Efficient Intravenous Therapy50/CS

The B Braun 473036 0.2 Micron Low Volume IV Filter is designed to enhance patient safety by effectively removing particulate matter, bacteria, and air from intravenous (IV) fluids. This add-on filter features a 0.2-micron pore size, ensuring high filtration efficiency while maintaining a low priming volume of 0.8 mL, which is crucial for precise fluid administration. Equipped with female Luer Lock and Spin-Lock connectors, this DEHP-free filter integrates seamlessly into various IV setups, providing a reliable solution for critical care environments.

Key Benefits

  • High Filtration Efficiency: The 0.2-micron filter effectively removes bacteria and particulate matter, reducing the risk of infections and complications during IV therapy.
  • Air Elimination: Designed to eliminate air bubbles from IV lines, preventing air embolism and ensuring patient safety.
  • Low Priming Volume: With a priming volume of only 0.8 mL, it minimizes fluid wastage, which is particularly beneficial in pediatric or critical care settings where precise fluid management is essential.
  • Secure Connections: The female Luer Lock and Spin-Lock connectors ensure a secure and leak-free connection, maintaining the integrity of the IV system.
  • DEHP-Free: Constructed without DEHP, reducing exposure to potentially harmful plasticizers and making it safer for all patient populations.

Compatibility and Applications

  • Compatibility: This IV filter is compatible with standard IV administration sets and can be easily integrated into existing IV therapy protocols.
  • Applications: Ideal for use in hospitals, outpatient clinics, and critical care units where high filtration efficiency and air elimination are paramount. It is particularly beneficial in scenarios requiring precise fluid administration, such as neonatal and pediatric care.

Usage Guidelines

  1. Preparation: Ensure the filter packaging is intact and the product is within its expiration date.
  2. Connection: Attach the filter to the IV administration set using the female Luer Lock connector, ensuring a secure fit.
  3. Priming: Prime the filter by allowing IV fluid to flow through until all air is expelled and the filter is fully saturated.
  4. Monitoring: Regularly monitor the filter during use for any signs of occlusion or air accumulation.
  5. Replacement: Replace the filter according to institutional protocols or if it becomes clogged to maintain optimal performance.

Certifications, Safety Standards, and Regulatory Approvals

  • FDA 510(k) Cleared: Approved for medical use in the United States, ensuring compliance with safety and performance standards.
  • ISO 13485 Certified: Manufactured under a certified quality management system, ensuring consistent product quality and reliability.
  • Latex-Free: Safe for patients sensitive to latex, reducing the risk of allergic reactions.

Comparison with Competitor Products

The B Braun 473036 IV Filter stands out due to its low priming volume and high filtration efficiency. While some competitor products may offer similar filtration capabilities, the combination of a 0.2-micron filter with a minimal priming volume provides a distinct advantage in settings where fluid conservation and precise dosing are critical.

Typical User Profile and Application Scenarios

  • Healthcare Professionals: Nurses, physicians, and clinical staff involved in administering IV fluids and medications in hospitals, clinics, and critical care environments.
  • Appropriate Scenarios: This filter is particularly useful in neonatal and pediatric care, oncology, and any setting where the removal of particulates and air from IV fluids is essential to patient safety.

Best Practices for Use and Maintenance

  • Inspection: Before use, inspect the filter for any damage or contamination.
  • Aseptic Technique: Use aseptic techniques when handling and connecting the filter to maintain sterility.
  • Monitoring: Continuously monitor the filter during infusion for any signs of blockage or air accumulation.
  • Replacement: Follow institutional guidelines for filter replacement to ensure ongoing efficacy and safety.

Regulatory and Safety Information

The B Braun 473036 IV Filter complies with all relevant FDA and ISO safety regulations, ensuring safe and effective use in clinical settings. Its latex-free design ensures compatibility with a wide range of patients, including those with material sensitivities.

How to Order

To purchase the B Braun 473036 0.2 Micron Low Volume IV Filter, visit the CIA Medical website, add the product to your cart, and complete the checkout process. For bulk orders or inquiries, contact CIA Medical customer service at (312) 275-5850 or submit a request for a quote using the contact form on the product page.

This IV filter provides healthcare professionals with a reliable, sterile, and efficient solution for safe and controlled IV therapy, ensuring optimal patient care across various medical environments.

Related Products