(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

B Braun 610373 - Micro-Introducer Kit, 4F x 10cm, Includes: (1) Micro-Introducer, (1) 21G x 4cm Echogenic Needle, (1) 0.018" x 40cm Guidewire (Nitinol with Platinum Tip), Standard Dilator - Precision Access for Safe and Controlled Vascular Procedures, 5/CS (Rx)

B Braun # 610373 - Micro-Introducer Kit, 4F x 10cm, Includes: (1) Micro-Introducer, (1) 21G x 4cm Echogenic Needle, (1) 0.018
Part Number B Braun 610373
SKU Number CIA8040689
Sell Unit CASE
Ships Within Special Order
List Price $451.27
Enter a valid quantity
Product Description

B Braun 610373 - Micro-Introducer Kit, 4F x 10cm, Includes: (1) Micro-Introducer, (1) 21G x 4cm Echogenic Needle, (1) 0.018" x 40cm Guidewire (Nitinol with Platinum Tip), Standard Dilator - Precision Access for Safe and Controlled Vascular Procedures, 5/CS (Rx)

The B Braun 610373 Micro-Introducer Kit is designed for safe, precise, and minimally invasive access in vascular procedures. This kit includes a 4F x 10cm micro-introducer, a 21G x 4cm echogenic needle, a 0.018" x 40cm nitinol guidewire with a platinum tip, and a standard dilator. It is an ideal solution for healthcare professionals performing procedures that require secure vascular access, such as catheter insertions, diagnostic angiography, and other interventions.

The echogenic needle improves visibility under ultrasound guidance, ensuring accurate placement, while the nitinol guidewire with a platinum tip offers flexibility and strength for safe navigation through the vascular system. The micro-introducer provides minimal trauma during insertion, making it a preferred choice for procedures requiring precision and safety. Pre-sterilized and ready for use, this kit ensures a sterile environment for patient care, reducing the risk of infection and complications.

Sheath SizeDilatorNeedleGuidewire MaterialGuidewire Tip Material
4 FrStandard4 cmNTPT


Key Benefits

The B Braun 610373 Micro-Introducer Kit offers several important benefits for healthcare professionals:

  • Enhanced Ultrasound Visibility: The 21G x 4cm echogenic needle enhances visibility during ultrasound-guided procedures, ensuring accurate needle placement and minimizing the risk of complications.
  • Flexible and Reliable Guidewire: The 0.018" x 40cm nitinol guidewire with a platinum tip provides strength and flexibility for smooth navigation through vascular anatomy, ensuring controlled access.
  • Minimal Trauma with Micro-Introducer: The 4F x 10cm micro-introducer is designed for minimal trauma during insertion, ensuring less discomfort for the patient while maintaining a secure access point for the procedure.
  • Pre-Sterilized and Ready to Use: The kit is pre-sterilized and ready for immediate use, ensuring that no additional preparation time is required, reducing the risk of contamination and saving valuable time.
  • Standard Dilator: The standard dilator is included to facilitate smooth and safe dilatation of the vessel, ensuring easy and effective catheter insertion.
  • Versatile and Compatible: The kit is compatible with a wide range of vascular access devices, making it versatile for various procedures.

Compatibility and Applications

The B Braun 610373 Micro-Introducer Kit is compatible with a wide range of vascular access devices and procedures, making it a versatile tool for healthcare professionals. It is commonly used for:

  • Vascular Access: Ideal for safely gaining access to blood vessels for diagnostic or therapeutic procedures, including angiography, catheter insertions, and stent placements.
  • Diagnostic Angiography: Suitable for diagnostic procedures where accurate vascular access is required for contrast media injection and imaging.
  • Catheter Insertions: Perfect for catheter-based procedures, including central venous access, hemodialysis catheter placements, and other similar interventions.
  • Minimally Invasive Procedures: Used in minimally invasive procedures that require precise access to the vascular system with minimal trauma to the patient.
  • Interventional Radiology: A common tool in interventional radiology procedures, where precise vascular access and minimal patient disruption are essential.

Usage Guidelines

To ensure the proper and safe use of the B Braun 610373 Micro-Introducer Kit, healthcare professionals should follow these guidelines:

  • Ultrasound Guidance: Use the echogenic needle under ultrasound guidance to accurately locate the desired vascular access site, minimizing the risk of complications and improving placement precision.
  • Guidewire Navigation: Gently advance the guidewire through the vessel, maintaining careful control to prevent accidental damage to the vascular wall. The platinum tip ensures smooth navigation and flexibility.
  • Minimize Trauma: The micro-introducer is designed for minimal trauma during insertion, but care should still be taken to avoid excessive force when inserting the introducer into the vessel.
  • Sterile Handling: Handle all components of the kit using sterile techniques to maintain the sterile field and prevent contamination.
  • Single Use Only: The kit is for single-use only. Once the procedure is completed, safely dispose of all components according to medical waste disposal protocols.

Certifications, Safety Standards, and Regulatory Approvals

The B Braun 610373 Micro-Introducer Kit complies with FDA and CE certifications, ensuring it meets stringent safety, quality, and performance standards for medical devices. These certifications offer healthcare professionals confidence in its safety and reliability during procedures.

Comparison with Competitor Products

Compared to other micro-introducer kits on the market, the B Braun 610373 stands out for its combination of features, including the echogenic needle for enhanced ultrasound visibility and the flexible yet strong nitinol guidewire with a platinum tip. These features provide added precision, safety, and efficiency in vascular procedures. The minimal trauma design of the micro-introducer ensures a safer and more comfortable experience for patients, setting this kit apart from others that may be less advanced or offer fewer specialized features.

Typical User Profile and Application Scenarios

The B Braun 610373 Micro-Introducer Kit is typically used by healthcare professionals such as interventional radiologists, vascular surgeons, cardiologists, and other specialists who require secure and precise vascular access. It is ideal for use in the following scenarios:

  • Interventional Radiology: Used in a variety of interventional radiology procedures where vascular access is required for imaging or therapeutic interventions.
  • Surgical and Postoperative Care: Often used in catheter insertions or access points required during surgeries or for postoperative monitoring.
  • Cardiology: Suitable for procedures like angiography or catheter placement in cardiology departments.
  • Outpatient Clinics: Ideal for outpatient clinics requiring vascular access for diagnostic or therapeutic purposes, including dialysis access.
  • Emergency Medicine: Used for emergency procedures that require quick and secure vascular access for contrast injections, catheterization, or other critical interventions.

Best Practices for Use and Maintenance

To ensure optimal performance and patient safety, healthcare professionals should adhere to these best practices:

  • Monitor Placement Carefully: Ensure that the echogenic needle is placed accurately under ultrasound guidance and verify proper guidewire placement before proceeding with catheter insertion.
  • Minimal Force: Always use minimal force when advancing the introducer, guidewire, and catheter to avoid trauma or injury to the vessel.
  • Sterile Handling: Maintain a sterile field at all times, handling the components with sterile gloves to prevent contamination.
  • Dispose After Use: Properly dispose of the kit components after the procedure, following medical waste disposal protocols to ensure safety.

Regulatory and Safety Information

The B Braun 610373 Micro-Introducer Kit is FDA-approved and CE-certified, meeting rigorous safety and quality standards for medical devices. These certifications provide healthcare professionals with the assurance that the kit is safe and reliable for use in clinical environments.

How to Order

Ordering the B Braun 610373 Micro-Introducer Kit is simple. Add the product to your cart and proceed through the secure checkout process. For bulk orders or additional inquiries, please contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page. Our team is happy to assist you with any questions or special requests regarding this product.

Related Products