B Braun 612143 - 6F 3-Piece Introducer Set with Echogenic Chiba Needle, Guidewire 0.018" x 60cm, and SS Mandrel, AU Coil, 10/CS (Rx)

B Braun # 612143 - 6F 3-Piece Introducer Set with Echogenic Chiba Needle, Guidewire 0.018
Part Number B Braun 612143
SKU Number CIA8039419
Sell Unit CASE
Ships Within Special Order
List Price $1,483.10
Enter a valid quantity
Product Description

B Braun 612143 - 6F 3-Piece Introducer Set with Echogenic Chiba Needle, Guidewire 0.018" x 60cm, and SS Mandrel, AU Coil, 10/CS (Rx)

The B Braun 612143 3-Piece Introducer Set is a high-quality medical device designed to facilitate accurate and efficient access to blood vessels or other internal organs during interventional procedures. This comprehensive set includes:

  • 6F Introducer Sheath (20cm): This sheath provides smooth insertion and seamless passage for various diagnostic and therapeutic devices.
  • 22G x 15cm Echogenic Chiba Needle: The echogenic properties of the needle enhance visibility under ultrasound guidance, ensuring precise placement during procedures.
  • 0.018" x 60cm Guidewire: The flexible guidewire allows for optimal maneuverability during catheter placement and other medical procedures.
  • SS Mandrel with AU Coil: These components provide durability, stability, and strength, making the introducer set reliable for demanding medical applications.

Designed for use in medical procedures such as catheter insertion, biopsies, and drainage, this set is a vital tool for achieving precise vascular access with minimal patient discomfort.

Key Benefits

The B Braun 612143 set offers several key benefits that enhance its utility for healthcare professionals:

  • Echogenic Needle for Enhanced Visibility: The 22G x 15cm Chiba needle features echogenic properties, improving visibility during ultrasound-guided procedures and allowing for precise needle placement, even in challenging anatomical areas.
  • Flexibility and Durability: The 0.018" guidewire is highly flexible, providing easy navigation through complex vascular pathways. The SS Mandrel and AU Coil technology ensure strength and stability during use.
  • Single-Use Sterile Design: The entire set is designed for single-use only, reducing the risk of infection and cross-contamination and ensuring a high level of patient safety.
  • Smooth Insertion: The 6F introducer sheath is crafted to ensure smooth passage of the guidewire and catheter, minimizing trauma to surrounding tissues and enhancing the overall ease of use.

Compatibility and Applications

This introducer set is compatible with a variety of medical devices, including diagnostic catheters, biopsy needles, and drainage tubes. It is ideal for use in hospitals, outpatient clinics, and diagnostic centers, where precise vascular access and accurate needle placement are crucial.

Applications include:

  • Vascular Access: Facilitating procedures such as angiography, catheterization, and central venous access.
  • Biopsy: Enabling precise needle placement for tissue biopsies, particularly in difficult-to-reach areas.
  • Drainage Procedures: Assisting in fluid drainage for various conditions where catheter insertion is necessary.

Its flexibility and echogenic needle make it especially effective in procedures requiring ultrasound guidance.

Usage Guidelines

To ensure safe and effective use of the B Braun 612143 introducer set:

  • Sterile Technique: Always handle the set using sterile techniques to maintain safety and minimize contamination risks.
  • Ultrasound Guidance: Use the echogenic needle with ultrasound to ensure precise placement.
  • Smooth Insertion: Carefully insert the introducer sheath to facilitate the passage of the guidewire and catheter.
  • Proper Disposal: Dispose of the introducer set after single-use following healthcare facility protocols for sharps disposal.

For more detailed instructions, refer to the products manual or the manufacturers website.

Certifications, Safety Standards, and Regulatory Approvals

The B Braun 612143 introducer set is certified by the FDA and bears the CE Mark, indicating its compliance with international safety standards. The FDA approval ensures the product meets strict U.S. regulatory requirements, while the CE Mark demonstrates its conformity with European medical device standards. These certifications assure healthcare providers that the product is safe, reliable, and effective for medical use.

Comparison with Competitor Products

Compared to other introducer sets, the B Braun 612143 offers enhanced features such as:

  • Echogenic Needle: Many competitor products lack the echogenic needle, which improves visibility during ultrasound-guided procedures and ensures accurate needle placement.
  • Flexibility of the Guidewire: The 0.018" x 60cm guidewire offers better maneuverability, allowing for smoother insertion through vascular pathways than many competitor options.
  • Durability of the SS Mandrel and AU Coil: These components provide superior strength and flexibility, ensuring reliability in high-demand procedures.

The combination of flexibility, visibility, and durability makes the B Braun 612143 set a preferred choice for healthcare professionals.

Typical User Profile and Application Scenarios

The B Braun 612143 set is typically used by:

  • Radiologists: For procedures such as ultrasound-guided biopsies, catheter insertions, and angiography.
  • Surgeons and Interventionalists: For vascular access and other interventional procedures.
  • Medical Technicians: Who assist in the preparation and execution of these medical interventions.

It is most commonly used in hospitals, outpatient clinics, and surgical centers, where precise vascular access is critical for both diagnostic and therapeutic applications.

Best Practices for Use and Maintenance

For optimal use and to extend the life of the B Braun 612143 introducer set, follow these best practices:

  • Use Ultrasound Guidance: Always use ultrasound to guide the placement of the echogenic needle for optimal accuracy.
  • Sterile Handling: Ensure all components are handled under sterile conditions to prevent contamination.
  • Dispose of Properly: After use, dispose of the entire set following your healthcare facilitys sharps disposal protocols to ensure safety.
  • Avoid Excessive Force: Handle the guidewire and introducer sheath gently to avoid damage and minimize trauma to the tissue.

Regulatory and Safety Information

The B Braun 612143 introducer set is manufactured under strict quality control guidelines to ensure compliance with FDA and CE regulations. These certifications guarantee the products reliability, safety, and performance in medical procedures. The set also adheres to the ISO 13485 quality management system standard, ensuring it meets high manufacturing and safety standards.

How to Order

To order the B Braun 612143 3-Piece Introducer Set, simply add it to your cart on the CIA Medical website and proceed to checkout. For bulk orders or further inquiries, please contact CIA Medical customer service at (312) 275-5850 or use the contact form available on our website. Our team is ready to assist with any questions you may have regarding your order or product specifications.

Related Products