(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

B Braun NF3140-10 - IV Administration Set for Horizon Pump with SafeLine and 3Y Configuration, 24/CS

B Braun # NF3140-10 - IV Administration Set for Horizon Pump with SafeLine and 3Y Configuration, 24/CS
Part Number B Braun NF3140-10
SKU Number CIA2227528
Sell Unit CASE
Ships Within 24 Hours
List Price $154.80
Enter a valid quantity
Product Description

B Braun NF3140-10 - IV Administration Set for Horizon Pump with SafeLine and 3Y Configuration, 24/CS

The B Braun NF3140-10 IV Administration Set is a high-performance intravenous delivery system designed specifically for Horizon infusion pumps. Featuring a 3Y configuration and SafeLine split septum injection sites, this set ensures safe, efficient, and reliable fluid delivery in various medical environments. Its user-friendly design and advanced safety features make it a preferred choice for healthcare professionals managing complex infusion therapies.

Product Overview

The NF3140-10 IV Administration Set is engineered for precision and safety in fluid administration. It is equipped with SafeLine injection ports, which provide needle-free access to maintain a closed system, minimizing contamination risks and enhancing patient safety. The 3Y configuration allows for simultaneous infusions, offering flexibility in administering medications, nutrients, or fluids. The set includes high-quality components such as a backcheck valve, pressure-limited check valve, and a SPIN-LOCK connector to ensure secure connections and consistent performance.

Key Features and Benefits

  • SafeLine Split Septum Injection Sites: Provides needle-free access, reducing the risk of needlestick injuries and ensuring a sterile environment.
  • 3Y Configuration: Three Y-sites at specific intervals (6, 68, and 108 inches above the distal end) allow for multiple infusions simultaneously or at different locations along the tubing, offering versatility in fluid management.
  • Backcheck and Pressure-Limited Check Valves: Prevent backflow and maintain proper pressure during infusion, ensuring consistent and accurate fluid delivery.
  • Universal Spike: Compatible with a variety of IV bags and containers, allowing for broad use in various clinical settings.
  • Free-Flow Protector and Roller Clamp: Enables precise control of fluid flow rates, safeguarding against accidental free flow and enhancing patient safety.
  • SPIN-LOCK Connector: Ensures a secure, leak-proof connection to IV access devices, minimizing disconnections during therapy.
  • Latex-Free Design: Reduces the risk of allergic reactions, ensuring safety for latex-sensitive patients.
  • Durable Tubing: Designed to withstand high pressure and repeated handling, ensuring reliable use in demanding environments.

Specifications

  • Drop Factor: 15 drops per mL
  • Tubing Length: Approximately 134 inches
  • Priming Volume: 27 mL
  • Injection Ports: SafeLine split septum injection sites
  • Configuration: 3Y design for multi-line infusions
  • Sterility: Packaged sterile for single use

Applications

The B Braun NF3140-10 IV Administration Set is ideal for a range of clinical applications, including:

  • Continuous Infusions: Delivering fluids, medications, or nutrients consistently over time.
  • Intermittent Infusions: Administering medications or solutions at specific intervals.
  • Simultaneous Infusions: Allowing multiple solutions to be infused concurrently through the 3Y configuration, ideal for complex treatment regimens.

Usage Guidelines

  1. Inspection: Verify that the packaging is intact and components are sterile before opening.
  2. Setup: Connect the universal spike to the IV bag or container and prime the tubing to remove air.
  3. Connection: Attach the SPIN-LOCK connector to the patients IV access device, ensuring a secure fit.
  4. Flow Adjustment: Use the roller clamp to regulate the flow rate as required for the therapy.
  5. Monitoring: Continuously monitor the infusion to ensure proper function and flow.
  6. Disposal: Dispose of the set after single use in accordance with local medical waste regulations.

Certifications and Safety Standards

The B Braun NF3140-10 IV Administration Set complies with FDA, ISO, and CE standards, ensuring safety, sterility, and performance. Its design meets rigorous healthcare protocols, offering reliable and effective infusion therapy.

Comparison with Competitor Products

The NF3140-10 distinguishes itself through its advanced 3Y configuration, SafeLine injection ports, and robust safety features, including backcheck and pressure-limited valves. These features provide superior reliability and flexibility compared to standard IV sets, making it a trusted choice for complex infusion needs.

Typical User Profile and Application Scenarios

This IV set is intended for use by healthcare professionals in hospitals, outpatient clinics, and long-term care facilities. It is particularly beneficial in scenarios requiring multiple or simultaneous infusions, such as critical care, oncology treatments, and complex fluid therapies.

Best Practices for Use and Maintenance

  • Maintain Sterility: Follow aseptic techniques during setup and use to prevent contamination.
  • Ensure Proper Connections: Verify that all connections are secure to prevent leaks or disconnections.
  • Single Use Only: Dispose of the IV set after use to comply with infection control standards.

How to Order

To order the B Braun NF3140-10 IV Administration Set for Horizon Pump with SafeLine and 3Y configuration, contact CIA Medical customer service at (312) 275-5850. Their team is ready to assist with inquiries and bulk order requirements.

Related Products