-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
BD 381433 - Insyte Autoguard Shielded IV Catheter 20 G x 1.00 inch with BD Vialon Catheter Material and BD Instaflash Needle Technology, 50 EA/BX
The BD 381433 Insyte Autoguard Shielded IV Catheter with BD Vialon Catheter Material and BD Instaflash Needle Technology is a high-performance intravenous (IV) catheter designed for safety, comfort, and ease of use in clinical settings. The catheter's 20 G x 1.00 inch configuration makes it suitable for a wide range of medical applications, including fluid administration, blood draws, and medication delivery.
Product Overview and Design Features
- BD Autoguard Shielding Mechanism: The catheter features the Autoguard safety technology, which automatically retracts the needle after insertion, reducing the risk of accidental needlestick injuries. This feature is vital for protecting healthcare professionals during IV insertions.
- BD Vialon Catheter Material: The catheter is made from BD Vialon, a proprietary material known for its flexibility and biocompatibility. This material softens inside the vein, reducing the risk of mechanical phlebitis and improving patient comfort.
- BD Instaflash Needle Technology: The Instaflash technology provides immediate visual confirmation of vessel entry by allowing a flash of blood in the needle hub. This helps clinicians confirm successful vein puncture on the first attempt, increasing success rates and reducing patient discomfort.
- 20 Gauge, 1.00 Inch: The 20 G needle size strikes a balance between flow rate and patient comfort, while the 1.00-inch length is optimal for many intravenous applications, including the administration of fluids and medications.
Intended Use in Medical Settings
The BD Insyte Autoguard IV Catheter is intended for use in a variety of clinical scenarios where IV access is required, such as:
- IV Fluid Administration: Used for delivering hydration, electrolytes, or blood products to patients.
- Medication Delivery: Suitable for intravenous medication administration, including antibiotics and pain management drugs.
- Blood Sampling: The catheter allows for quick and efficient blood draws, which is critical in emergency or routine clinical settings.
Benefits for healthcare professionals:
- Increased Safety: The automatic needle retraction mechanism significantly reduces the risk of needlestick injuries, enhancing workplace safety.
- Faster Venous Access: The Instaflash technology improves first-attempt success rates, reducing the need for multiple insertion attempts.
- Improved Patient Comfort: The Vialon material softens after insertion, making the catheter more comfortable for patients during prolonged use.
Certifications, Safety Standards, and Regulatory Approvals
- FDA Approval: The BD Insyte Autoguard IV Catheter is cleared by the FDA for use in the U.S., meeting strict regulatory standards for safety and effectiveness.
- ISO Certification: The product complies with ISO 10555-5 standards for intravascular catheters, ensuring high quality and performance in clinical settings.
- Latex-Free: The catheter is made without latex, making it suitable for use with patients who have latex allergies.
Comparison with Other Market Products
Below is a comparison between the BD Insyte Autoguard IV Catheter and similar products available in the market:
Feature | BD Insyte Autoguard | AngioDynamics IV Catheter | Smiths Medical Jelco IV Catheter |
---|---|---|---|
Gauge | 20 G | 20 G | 20 G |
Needle Safety Mechanism | Autoguard Retractable | Push-button safety | Manual retraction |
Catheter Material | BD Vialon | Teflon | Polyurethane |
Instaflash Technology | Yes | No | Yes |
FDA Approved | Yes | Yes | Yes |
Price Point | Moderate | Low | High |
Patient Comfort | High | Moderate | High |
Unique Features:
- Instaflash Technology: The immediate blood flash confirmation is a key feature not available in all IV catheters, making the BD Insyte Autoguard stand out in terms of reducing failed IV attempts.
- Autoguard Shielding: The automatic needle retraction offers a significant advantage over manual or push-button safety mechanisms, providing superior protection against needlestick injuries.
Common User Profile and Typical Scenarios
The BD Insyte Autoguard IV Catheter is typically used by:
- Nurses and Phlebotomists: These healthcare professionals frequently insert IV catheters and rely on the safety and ease-of-use features of the Autoguard system to reduce the risk of injury and improve patient outcomes.
- Emergency Medical Technicians (EMTs): In emergency scenarios, EMTs need quick, reliable venous access, and the Instaflash technology ensures rapid insertion with high success rates.
- Hospital Physicians: Physicians in hospital settings use the catheter for delivering medications and fluids efficiently, particularly in high-stress, high-volume environments like emergency departments or ICUs.
Typical scenarios include:
- Emergency IV Access: In trauma cases or acute medical emergencies, this catheter ensures fast and reliable access to the bloodstream for administering life-saving fluids or medications.
- Routine Blood Draws: In outpatient clinics or hospital wards, the catheter is also used for blood sampling, offering a safer alternative to traditional IV devices.
Best Practices for Using and Maintaining the Product
To ensure optimal performance and safety when using the BD Insyte Autoguard IV Catheter, follow these best practices:
- Proper Insertion Technique: Always adhere to aseptic techniques when inserting the catheter to avoid infections. Ensure the catheter is correctly aligned with the vein for the best insertion success.
- Use the Instaflash Indicator: Watch for the immediate blood flash in the catheter hub to confirm venous access. This allows for precise placement and reduces the need for multiple attempts.
- Safe Needle Disposal: After insertion, ensure that the needle retracts properly into the Autoguard housing. Always dispose of used catheters in appropriate sharps disposal containers.
- Patient Monitoring: Once the catheter is inserted, periodically check the site for signs of infiltration or phlebitis, especially during extended use.
By following these best practices, healthcare providers can ensure that the BD Insyte Autoguard IV Catheter is used safely and effectively, contributing to better patient outcomes and workplace safety.
BD #381433, BD 381433 Insyte Autoguard Shielded IV Catheter with BD Vialon Catheter Material and BD Instaflash Needle Technology, Pink, Straight, 200/CS
$479.22 per CASE
BD #381433, Insyte Autoguard Shielded IV Catheter with BD Vialon Catheter Material and BD Instaflash Needle Technology, Pink, Straight, 50/BX
$175.47 per BOX