(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 382534 - BD Insyte Autoguard BC Shielded IV Catheter With Blood Control Technology, Pink, Non Winged, 50/Box, 4 Box/CS

BD  # 382534 - BD Insyte Autoguard BC Shielded IV Catheter With Blood Control Technology, Pink, Non Winged, 50/Box, 4 Box/CS
Part Number BD 382534
SKU Number CIA7008751
Sell Unit CASE
Ships Within Special Order
List Price $549.50
Enter a valid quantity
Product Description

BD 382534 - BD Insyte Autoguard BC Shielded IV Catheter With Blood Control Technology, Pink, Non Winged, 50/Box, 4 Box/CS

BD Insyte Autoguard BC Shielded IV Catheter With Blood Control Technology

BD 382534 Insyte Autoguard BC Shielded IV Catheter With Blood Control Technology

The BD Insyte Autoguard BC shielded IV catheter with blood control technology is clinically demonstrated to reduce the risk of blood exposure by 95%. BD blood control technology minimizes blood exposure, cleanup time and use of supplies associated with blood spills.

  • Safety IV catheter designed to reduce blood exposure and needlestick injury
  • Blood control technology designed to stop blood flow from the catheter hub once, at insertion

Blood leakage prevention septum

Increased safety

First-stick success

Minimized phlebitis

You do not need to worry about stopping blood during initial insertion with the BD Insyte Autoguard BC catheter.BD Insyte Autoguard IV catheters demonstrated a statistically significant 95% reduction in needlesticks.BD Instaflash needle technology on the 20-G, 22-G and 24-G sizes incorporates a notched needle to improve first-stick success and reduce painful hit-and-miss insertions.BD Vialon biomaterial softens up to 70% in the vein, enabling longer dwell times3 and reducing the chance of mechanical phlebitis by up to 50%
Catalog No. (Non Winged | Winged)
ColorGaugeLength (in)
382534Pink201.16 in.
Catheter ID (mm)Catheter OD(mm)Gravity Flow Rate (mL/min)High Pressure Rating (psi)
0.7620 - 0.83821.0414 - 1.117661300

Clean, easy and efficient for clinicians and patients

You strive for a clean IV placement every time, but when you have to apply pressure while activating the devices safety mechanism and connecting the extension, blood spills can happen.

The BD Insyte Autoguard BC shielded IV catheter with blood control technology addresses these challenges:

  • No venous compression required during insertion
  • Less mess and minimized healthcare worker risk resulting from blood leakage
  • Needlestick injury protection
  • Less blood leakage means less disruption during the patients care

Built-in blood leakage prevention

No need to worry about stopping blood during insertion with BD Insyte Autoguard BC catheters.

Stop blood leakage without the need for venous compression - the unique design allows a one-handed insertion technique with blood flow resuming when an add-on device is connected.

Clinically demonstrated to reduce the risk of blood exposure by 95% - reducing staff exposure to blood as well as surface contamination.


Safety at the push of a button

The BD Insyte Autoguard BC catheter is tailored for the clinicians safety and insertion success, leaving you feeling confident in each insertion, and your patients feeling confident in you.

Demonstrated to reduce needlestick injuries by 95%

  • Push-button needle shielding technology
  • Fully encapsulated needle

The right IV catheters, right from the start

BD Vialon Biomaterial

The catheter material is designed to resist kinking and softens up to 70% in the vein, enabling longer dwell times and reducing the chance of mechanical phlebitis by up to 50%.

BD 382534 Insyte Autoguard BC Shielded IV Catheter Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437):No
Device labeled as "Not made with natural rubber latex":No
For Single-Use:Yes
Prescription Use (Rx):Yes
Over the Counter (OTC):No
Kit:No
Combination Product:No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P):No
Related Products