-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Achieve Coaxial Biopsy Systems
The Achieve biopsy system from BD gives you the pr" alt="Carefusion # CA1411 -
Achieve Coaxial Biopsy Systems
The Achieve biopsy system from BD gives you the pr" itemprop="image"/>
Carefusion CA1411 -
Achieve Coaxial Biopsy Systems
The Achieve biopsy system from BD gives you the pr
Achieve Coaxial Biopsy Systems
The Achieve biopsy system from BD gives you the precise control and quality sampling capability you need when working with calcified or fibrous lesions. This lightweight automated system offers spring-loaded action for fast, accurate penetration of dense tissue. It is also available with a coaxial introducer for multiple sampling from one percutaneous puncture with minimal damage to surrounding tissue.
The system has two programmable firing modes: automatic and delay mode. In automatic mode, the cannula and stylet release in rapid sequence to capture the specimen with the push of a button. In delay mode, the stylet releases first to allow time for tissue to settle in the sample notch; the clinician then verifies and documents the stylet position, repositions if necessary and activates the cutting cannula.
- One-handed design for convenient manipulation of an ultrasound transducer
- Echogenic markings on the cannula and stylet to support precise ultrasound positioning
- Optional coaxial introducer for multiple sampling
- 20 mm sample notch
The Achieve biopsy device is commonly used for the following biopsy procedures:
- Breast
- Kidney
- Liver
- Prostate
Manufacturer Part Number | Manufacturer Name | Gauge Size | Biopsy needle size | Introducer needle size | Usable length |
CA1411 | Carefusion | 14G | 14G x 11cm | 13.5G x 6cm | 5cm |
Device Characteristics
What MRI safety information does the labeling contain? | Labeling does not contain MRI Safety Information |
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437): | No |
Device labeled as "Not made with natural rubber latex": | No |
For Single-Use: | Yes |
Prescription Use (Rx): | Yes |
Over the Counter (OTC): | No |
Kit: | No |
Combination Product: | No |
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P): | No |
The Achieve Biopsy Device Offers Three Firing Modes for Procedural Flexibility
Product Features
Convenience
- 35% lighter in weight than other automatic devices, making the system ideal for CT and ultrasound-guided procedures
- One-handed design simplifies loading and operation and allows for convenient manipulation of guidance device (ultrasound transducer)
- Available with coaxial introducer for multiple sampling from one percutaneous puncture with minimal damage to surrounding tissue
Quality
- 20mm sample notch and thin-wall cannula for larger core
- Reliable sample retrieval-reduced risk of sample loss
Warning
Test firing the needle may damage the cutting cannula and/or stylet tip. Keep fingers or other objects from in front of the needle as it will advance 2.5 cm very rapidly when activated. Never test fire the instrument in an unsafe direction.
Instruction for Use
Step 1: Preparation of Achieve for Use
To charge the Achieve biopsy device, simply pull back on the charging arm and release twice, first to charge the cutting cannula, the second to charge the inner stylet.
Step 2: Position the Needle
Position the needle tip at or near the edge of the region to be sampled.
Step 3: Fire the Instrument
Two firing sequence methods are available once the Achieve biopsy device is charged.
- Delay ModeDepression of the D button releases the inner stylet into the sample area. The operator uses this delay firing method to verify the position of the sample notch in the target area prior to depressing the A button which activates the cutting cannula, capturing the tissue sample.
- Automatic ModeThe operator can choose the fully sequential mode, omitting the delay feature, simply by depressing the A button first. This releases the stylet and cutting cannula in sequence, capturing the tissue sample.
A=Automatic Mode
D=Delayed Mode (Stylet Only)
Step 4: Biopsy Specimen
To retrieve the tissue sample, hold the instrument with the A and D firing buttons facing up, and pull back and release the charging arm once. This action will retract the outer cutting cannula exposing the stylet notch with the tissue sample.
Step 5: Obtaining Multiple Samples
After the tissue sample is removed, additional samples from the same patient may be obtained by pulling the charging arm a second time, which will retract the stylet within the cutting cannula, placing the Achieve biopsy device once again in a fully charged position. Repeat Steps 3-5. In the automatic mode, the Achieve automatic biopsy device is designed to fire the cannula and stylet in rapid succession. Please exercise caution before proceeding as the device will advance 2.5 cm when activated.
Caution
For single use only. Re-use may result in a non-functional product or contribute to cross contamination. Only clinicians who have been properly trained in this procedure, including patient preparation, sample preservation and the use of image guidance for percutaneous biopsy, should use this device.