Cook Medical G31138 - SHEATH, KSAW-6.0-38-90-RB-SHTL-FLEX-HC, EACH

Cook Medical # G31138 - SHEATH, KSAW-6.0-38-90-RB-SHTL-FLEX-HC, EACH
Part Number Cook Medical G31138
SKU Number CIA2247401
Sell Unit EACH
Ships Within 2-3 Days
List Price $527.05
Enter a valid quantity
Product Description

Cook Medical G31138 - SHEATH, KSAW-6.0-38-90-RB-SHTL-FLEX-HC, EACH

Flexor Shuttle Select ‒ a Component of the Shuttle Select Carotid Access System

Used to introduce balloons, closed and non-tapered end catheters or other diagnostic and interventional devices.

Flexor Introducers and Guiding Sheaths are designed to perform as a guiding sheath and/or introducer sheath. Flexor Introducers and Guiding Sheaths incorporate a Flexor shaft with a hemostasis valve and are provided with one or more dilators. These devices are available in various sizes, lengths and configurations. Configurations include differences in shaft construction, such as varying shaft stiffness and distal tip material and shape, dilator material, hydrophilic coating and/or distal radiopaque markers. Refer to the product label for product specifications (i.e., sheath inner diameter, dilator inner diameter, distal curve configuration, hemostasis valve design).

  • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression.
  • Radiopaque band, incorporated within sheath material, identifies precise location of sheaths distal tip for positioning accuracy.
  • Stiffened proximal shaft design enables superior trackability and support for devices.
  • Atraumatic tip with unique transition zone reduces vessel trauma during engagement.
  • Selective feature that allows the sheath to be paired with a compatible selective catheter (sold separately), minimizing the exchange of parts.
  • AQ hydrophilic coating provides an extremely lubricous surface area for enhanced trackability.
  • Tuohy-Borst manual-adjusting valve seal minimizes blood loss during device insertion.

90 cm Length

Order NumberReference Part NumberFrID mmLength cmAccepts Wire Guide Diameter inch
G31138KSAW-6.0-38-90-RB-SHTL-FLEX-HC62.2900.038

Intended Use

Flexor Introducers and Guiding Sheaths are intended to introduce therapeutic or diagnostic devices into the vasculature, excluding coronary and neuro vasculature.

Precautions

  • This product is intended for use by physicians trained and experienced in diagnostic and interventional techniques. Standard techniques for placement of vascular access sheaths should be employed.
  • In order to ensure device compatibility, choose a sheath size large enough to accommodate the maximum outer diameter of any devices that will be placed through the sheath.
  • All interventional or diagnostic instruments used with this product should move freely through the valve and sheath to avoid damage.
  • Do not attempt to heat or reshape the device.
  • When inserting, manipulating or withdrawing a device through the sheath, always maintain sheath position.
  • When puncturing, suturing or incising the tissue near the sheath, use caution to avoid damaging the sheath.
  • The potential effects of phthalates on children or pregnant/nursing women have not been fully characterized and there may be concern for reproductive and developmental effects.

Potential Adverse Events

Adverse events that may be associated with the use of an introducer set include, but are not limited to:

  • Bleeding
  • Extravasation
  • Hematoma
  • Vessel laceration
  • Vessel perforation
  • Local inflammation
  • Local pain
  • Access site infection
  • Distal embolization

Instructions for Use

Sheath Introduction

  • Ensure that the inner diameter (ID) of the sheath is appropriate for the maximum diameter of the instruments to be introduced.
  • Using the side-arm of the valve, flush the sheath by filling the sheath assembly completely with heparinized saline.
  • Flush the dilator with heparinized saline.
  • Insert the dilator completely into the sheath. If the sheath has a Tuohy- Borst valve, tighten the valve around the dilator.
  • If the device has hydrophilic coating, activate the coating by wetting the outer surface of the device with heparinized saline. NOTE: For best results, maintain wetted condition of device during placement.
  • Using standard Seldinger technique, access the target vessel with the appropriate needle.
  • Insert a wire guide into the vessel through the needle.
  • Leave the wire guide in place and remove the needle.
  • Insert the dilator/sheath assembly over the wire guide.
  • Remove the wire guide and dilator, then aspirate and flush through the sheath side-arm.
  • Insert appropriately sized device(s) as needed.

Sheath Removal

  • Insert a wire guide until its tip extends at least 10 cm past the tip of the sheath.
  • Remove the sheath. Avoid applying traction to hub during removal. If resistance is anticipated or encountered during withdrawal of the Flexor sheath, consider reinserting the dilator and removing the sheath and dilator as a unit.
  • Remove the wire guide.

How Supplied

Supplied sterilized by ethylene oxide gas in peel-open packages. Intended for one-time use. Sterile if package is unopened or undamaged. Do not use the product if there is doubt as to whether the product is sterile. Store in a dark, dry, cool place. Avoid extended exposure to light. Upon removal from package, inspect the product to ensure no damage has occurred.