Cook Medical G53564 - GUIDEWIRE, .038X145CM AMPL, AES-038145-DF, EACH

Cook Medical # G53564 - GUIDEWIRE, .038X145CM AMPL, AES-038145-DF, EACH
Part Number Cook Medical G53564
SKU Number CIA2173842
Sell Unit EACH
Ships Within 24 Hours
List Price $73.52
Enter a valid quantity
Product Description

Cook Medical G53564 - GUIDEWIRE, .038X145CM AMPL, AES-038145-DF, EACH

Amplatz Fixed Core Wire Guide

Amplatz wire guides are used to gain ureteral access, to establish a tract, and to assist in the placement, replacement and exchange of medical devices during urological procedures.

Order NumberReference Part NumberDiameter inchLength (cm)Tip Con gurationCoating
G53564AES-038145-DF0.0381455 cm double exiblePTFE

Intended Use

Wire Guides are used to gain ureteral access, to establish a tract, and to assist in the placement, replacement, and exchange of medical devices during urological procedures. These wire guides are not intended for PTCA use.

Precautions

  • When exchanging or withdrawing an instrument over the wire guide, secure and maintain the wire guide in place under fluoroscopy in order to avoid unexpected wire guide displacement.
  • Manipulation of wire guide requires appropriate imaging control. Use caution not to force or over manipulate the wire guide when gaining access.
  • When using wire guide through a metal cannula/needle, use caution as damage may occur to outer coating.

Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437):No
Device labeled as "Not made with natural rubber latex":No
For Single-Use:Yes
Prescription Use (Rx):Yes
Over the Counter (OTC):No
Kit:No
Combination Product:No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P):No

Instructions for Use

  • Using aseptic technique, remove the wire from its outer packaging and place in the sterile field.
  • Remove the wire guide from the holder.
  • Advance the flexible end of the wire guide into the device and position to the desired anatomical location. NOTE: Endhole size and length of the device must be taken into consideration to ensure proper fit between wire guide and device.
  • After wire guide use is complete, remove from patient and discard.

How Supplied

Supplied sterilized by ethylene oxide gas in peel-open packages. Intended for one-time use. Sterile if package is unopened or undamaged. Do not use the product if there is doubt as to whether the product is sterile. Store in a dark, dry, cool place. Avoid extended exposure to light. Upon removal from package, inspect the product to ensure no damage has occurred.

CAUTION: U.S. federal law restricts this device to sale by or on the order of a physician (or properly licensed practitioner).