Covidien 8886259143 - SUTURE, FLEXON, 24", 3-0, T-31-CS-3/V-23SC, 12/BX

Covidien # 8886259143 - SUTURE, FLEXON, 24
Part Number Covidien 8886259143
SKU Number CIA2247886
Sell Unit BOX
Ships Within 24 Hours
List Price $475.85
Enter a valid quantity
Product Description

Covidien 8886259143 - SUTURE, FLEXON, 24", 3-0, T-31-CS-3/V-23SC, 12/BX

Covidien 8886259243 Flexion Temporary Cardiac Pacing Lead, Taper Point, Size 3-0, 24", SC-2, CV-23, 1/2 Circle, Clear (Pack of 12)

Flexon temporary cardiac pacing leads are specifically designed to insulate the lead and be less traumatic during removal after pacing is complete. They are indicated for use in temporary atrial and ventricular pacing and sensing during and after cardiac surgery.

  • Provides insulation and ease of removal
  • Improved safety to both patient and surgeon as pacing wires are visible and identifiable by color (especially when using multiple stands for bipolar pacing)
  • Eliminates requirement to cut needle and provides convenience to the clinician
  • Less traumatic during removal of temporary pacing lead

Product Information

StructureMultifilament
Suture TypeNon-Absorbable
CompositionStainless Steel
CoatingFEP Polymer, or PTFE Polymer
ColorClear, Orange, White
Tensile StrengthPermanent
Absorption ProfilePermanent

Indications

Flexon suture temporary cardiac pacing lead is indicated for use in temporary atrial and ventricular pacing and sensing during and after cardiac surgery.

Contraindications

  • When permanent pacing or monitoring is required, the use of Flexon suture temporary cardiac pacing lead is contraindicated.
  • The use of this product is contraindicated in patients with known sensitivities or allergies to its components.
  • The particular medical condition and anatomy of the patient may dictate the lead system and implantation procedure to be used.

Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437):No
Device labeled as "Not made with natural rubber latex":No
For Single-Use:Yes
Prescription Use (Rx):Yes
Over the Counter (OTC):No
Kit:No
Combination Product:No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P):No