Deroyal HNICU-37 - Neonatal Temperature Probe Hydrogel with Reflective Gray Sensor Cover, Compatible with Datex-Ohmeda Giraffe, 50 EA/CS

Product Overview

The Deroyal HNICU-37 Neonatal Temperature Probe is designed for precise and reliable temperature monitoring in neonatal care. This one-piece, direct plug-in probe features an adhesive hydrogel pad for gentle and secure skin contact. The reflective gray sensor cover minimizes external temperature interference, ensuring accurate readings. Compatible with Datex-Ohmeda Giraffe systems, this disposable, non-sterile probe is an essential tool for NICUs and pediatric care settings.

Key Benefits

  • Hydrogel Pad for Secure Contact: Provides gentle adhesion to neonatal skin, reducing discomfort.
  • Reflective Gray Sensor Cover: Enhances accuracy by shielding the sensor from external factors.
  • Direct Plug-In Design: Ensures quick and easy connection to monitoring systems.
  • Compatible with Datex-Ohmeda Giraffe: Seamlessly integrates with widely used neonatal monitoring systems.
  • Disposable and Hygienic: Promotes patient safety by reducing cross-contamination risks.

Product Details of Deroyal HNICU-37

Product No.ColorProbe CoverMachines And ManufacturersReplaces Probe NumberShape
HNICU-37 (Disposable Probe)PuttyCover Hydrogel Temperature Skin Senso w/o Foam 7/8"GE Giraffe OmniBed, Giraffe Incubators, Giraffe Warmers & Panda Warmers"CareFusion 10-1910-020, 10-1910-060 GE 6600-0873-700 & 6600-0874-700 Level 1's STS-209"Deroyal HNICU-37

Deroyal HNICU-37 Neonatal Skin Temperature Sensor Probes Benefits

  • Provides comfortable and precise management of neonatal patients' vital signs.
  • Compatible with the most common neonatal temperature monitoring and warming equipment.
  • Available in a one-piece completely disposable design (HNICU series probes) or through a connecting interface cable (FNICU series probes).
  • Unique color-coding system ensures proper sensor identification during use and storage.
  • Reflective sensor cover deflects radiant heat for more accurate readings.
  • Disposable replacement pads available in choice of hydrogel or adhesive pads to adhere to fragile infant skin without irritation.
  • Packaged 50 probes per case.
  • Interface cable is 3ft (0.91m) in length

Deroyal HNICU-37 Neonatal Skin Temperature Sensor Probes Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)No
Device labeled as "Not made with natural rubber latex"Yes
For Single-UseYes
Prescription Use (Rx)No
Over the Counter (OTC)No
KitNo
Combination ProductNo
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)No

Compatibility and Applications

This temperature probe is fully compatible with Datex-Ohmeda Giraffe systems and is widely used in NICUs, pediatric hospitals, and outpatient care facilities. It provides real-time, precise temperature monitoring for premature and newborn infants in critical care environments.

Usage Guidelines

Attach the probes hydrogel pad to the neonates skin, ensuring proper placement of the reflective sensor. Connect the probe directly to the compatible monitoring system for accurate temperature readings. Dispose of the probe after single use to maintain hygiene.

For detailed instructions, consult the product manual or seek professional guidance.

Certifications, Safety Standards, and Regulatory Approvals

The Deroyal HNICU-37 Temperature Probe meets healthcare safety and quality standards, ensuring dependable and safe performance in neonatal monitoring.

Comparison with Competitor Products

The Deroyal HNICU-37 stands out for its hydrogel pad, reflective gray sensor cover, and compatibility with Datex-Ohmeda systems, offering superior accuracy and patient comfort compared to standard neonatal probes.

Typical User Profile and Application Scenarios

This probe is ideal for healthcare professionals in NICUs and pediatric care units who require continuous, precise temperature monitoring for neonates.

Best Practices for Use and Maintenance

  • Inspect the probe for damage before use to ensure reliability.
  • Follow institutional protocols for aseptic application and safe disposal.
  • Store in a clean, dry environment before use to maintain product quality.

How to Order

To purchase the Deroyal HNICU-37 Neonatal Temperature Probe Hydrogel with Reflective Gray Sensor Cover, add it to your cart and complete the secure checkout process. For bulk inquiries or additional assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form available on this page.