-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Avanos Medical 22703 - Ballard Turbo CS Adult, 14 FR, DSE, 20 EA/CS
Avanos 22703 Avanos BALLARD Turbo-Cleaning Closed Suction System have advanced infection control features that redefine the standard of care for closed suctioning. BALLARD Turbo-Cleaning catheter is the only catheter that retracts within a unique, isolated, turbulent cleaning chamber. The turbulent cleaning action results in an 89% cleaner catheter tip compared to a standard closed suction system. This reduced colonization may help reduce risk of VAP in your ventilated patients.
Leader in closed suctioning for more than 30 years, BALLARD Standard Closed Suction Systems are a powerful tool in your fight against VAEs. They are designed to remove secretions from the airway while maintaining ventilation and oxygen therapy throughout the suctioning procedure. Closed-suction systems reduce the potential risk for the spread of infection and contamination entering the airway and protects the caregiver from cross-contamination.
Ventilator-associated pneumonia (VAP) is the most common and deadly healthcare-associated infection, affecting up to 28% of ventilated patients.
The Avanos BALLARD Turbo-Cleaning Closed Suction System retracts with a unique and isolated turbulent cleaning chamber, making it the only catheter proven to reduce bacterial load on the catheter tip by 89% in a 72-hour period.2 The presence of such a valve should be considered essential in preserving lung volumes and uninterrupted ventilation in mechanically ventilated patients.
Avanos 22703 Ballard Turbo CS Adult, 14 FR, DSE Features
- Sealed by our patented PEEP seal technology
- One-way lavage port designed to prevent sprayback
- Hinged valve isolates catheter tip and helps prevent inadvertent lavage
- Turbulent cleaning chamber creates cleansing action, resulting in a cleaner catheter
- PEEP seal helps reduce PEEP loss and inadvertent lavage
- Integrated MDI Port (Optional)
Avanos 22703 Ballard Turbo CS Adult, 14 FR, DSE Features Include
- Patented PEEP seal technology helps reduce PEEP loss and helps prevent inadvertent lavage
- One-way lavage port prevents splash-back, which reduces the risk of cross-contamination
- Dynamic valve technology allows for normal ventilation during catheter cleaning
Avanos 22703 BALLARD Turbo-Cleaning Closed Suction System Reduces:
- The risk of contamination from outside pathogens4
- Colonization within the circuit4
- ICU days and associated costs5
- Potential exposure to bodily fluids
Avanos 22703 Ballard Turbo CS Proven To Provide An 89% Cleaner Catheter Tip
Manipulation of The Ventilator Circuit Can Increase Cross-Contamination - A Leading Cause of VAP
- Ventilator-associated pneumonia (VAP) is the most common and deadly healthcare-associated infection, affecting up to 28% of ventilated patients. To help protect patients, a closed ventilator circuit is recognised as a best practice in the prevention of VAP
- Maintaining a closed ventilator circuit is recommended by the American Association for Respiratory Care (AARC)
- A closed circuit maintains ventilation and oxygen therapy throughout suctioning, and prevents approximately 50% of the lung volume fall observed when suctioning after disconnection from the ventilator
- Closed suctioning is a best practice that protects patients and caregivers
- Reduces the risk for contamination from outside pathogens
- Reduces colonisation within the circuit5
- Designed to protect caregivers from exposure to body fluids
Avanos Ballard Turbo CS Adult, 14 FR, DSE 22703 Instructions for Use
Setup:
- Select appropriate size Avanos 22703 BALLARD Turbo-Cleaning catheter.
- Attach thumb control valve to suction tubing.
- Depress and hold thumb valve and simultaneously adjust vacuum regulator to desired level.
- Release thumb control valve and attach Avanos BALLARD catheter between patient and the ventilator circuit.
Suggested Suction Procedure:
- Stabilize Avanos BALLARD catheter and endotracheal (ET) adapter with one hand then push the catheter into the endotracheal tube with the thumb and forefinger of the opposite hand (Fig. 1).
- Advance catheter to desired depth.
- Depress and hold thumb control valve, then gently withdraw catheter. Stop withdrawal when black marking ring is visible inside sleeve (Fig. 2).
- Release thumb control valve.
- Repeat steps 1 through 4 above as necessary.
Patient Lavage Instructions:
- For intubated patient, advance catheter 10-13 cm (4-5 inches) into the endotracheal tube. For tracheostomy patient, advance the catheter 3-4 cm (1.5-2 inches) into the tracheostomy tube.
- Instill desired amount of fluid into the lavage port.
- Advance catheter to desired depth and follow the above suggested suction procedure.
Catheter Irrigation Instructions:
- Be sure that the black ring is visible inside the sleeve (Fig. 2). Open cap on the irrigation port.
- Insert saline vial (REF 116 or REF 117) into irrigation port.
- Intermittently depress and release thumb valve (Fig. 6) until the catheter and chamber are clear (Fig. 5), or until the vial is empty.
- Lift and turn the thumb valve lock. Control Depth Suction
(Catheters printed with numerical markings only):
- Align any printed depth number on the catheter with the similar number printed on the endotracheal tube, or observe the printed number on the endotracheal tube closest to the endotracheal tube adapter.
- Add 6 cm to this number.
- Advance catheter until the sum (depth plus 6) appears in the window directly across from irrigation port connector.
- Catheter tip will be within 1 cm of the end of the artificial airway.
Control Depth Suction:
- Follow all the steps above except steps 2 and 3; add 8 to the number.
Thumb Control Valve Operation:
- The thumb control valve can be locked to prevent inadvertent or accidental suction. To lock, lift white part of thumb control valve and rotate 180 degrees. To unlock, repeat this action (Fig. 4).
Day Sticker Usage:
- Avanos BALLARD Turbo-Cleaning catheter may be used for no more than 72 hours. All other Avanos BALLARD closed suction catheters are to be used for no more than 24 hours only.
- Apply the appropriate day sticker to the thumb control valve.
Example: If Avanos BALLARD Turbo-Cleaning catheter is opened on Monday, place the Thursday sticker on the thumb control valve. For any other REF, place the Tuesday day sticker on the thumb valve.
Avanos Ballard Turbo CS Adult, 14 FR, DSE 22703 Device Characteristics
What MRI safety information does the labeling contain? | Labeling does not contain MRI Safety Information |
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437): | No |
Device labeled as "Not made with natural rubber latex": | No |
For Single-Use: | Yes |
Prescription Use (Rx): | No |
Over the Counter (OTC): | No |
Kit: | No |
Combination Product: | No |
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P): | No |
Avanos Ballard Turbo CS Adult, 14 FR, DSE 22703 Specifications
Name | Value |
---|---|
Age | Adult |
Diameter (Fr) | 14 |
Made With DEHP | No |
Single Use | True |
Sterile | Yes |
Sterilization Method | GAMMA |
Catheter Length (In.) | 12.5 |
MDI Attachment | No |
Primary Product Color | Deep Green |
Product Brand | BALLARD |
Kit, Pack, or Tray | False |
Avanos Medical #22705, Ballard Turbo CS Adult, 14 FR, T-Piece, 20 EA/CS
$753.00 per CASE
Avanos Medical #2205, Ballard Turbo CS Adult, 14 FR, T-Piece, 20 EA/CS
$575.87 per CASE
Avanos Medical #227147, BALLARD Turbo-Cleaning Closed Suction System, ADULT, 14 FR, DSE, DL, 20 EA/CS
$480.15 per CASE