Product Description

Polymedco ESR-2CT - Sed-Chek 2, Bi-Level, with RBCs, 6x8ml, ESR Control, 6/Set

A whole blood reference control material designed to monitor ESR (Erythrocyte Sedimentation Rate) procedures. Helps to monitor technique as well as environmental, physical and mechanical factors such as room temperature, and tube position, vibration or instrument problems. Sed-Chek 2 is an advanced formula and is the most comprehensive ESR control assayed for both automated and manual methods.

Unique cell-stabilizing process mimics the rouleaux formation of patient samples.

  • Bi-level, whole-blood control designed to monitor ESR procedures.
  • Monitor technique as well as environmental and physical factors that adversely affect ESR results.
  • Run like a patient samplenot necessary to void diluent from pre-filled tubes.
  • Universal control assayed for both automated and manual ESR methods.
The erythrocyte sedimentation rate test is a variable test where the result can be affected by environmental and procedural factors. Sed-Chek 2, a bi-level whole blood control, was designed for use with manual methods and automated ESR analyzers to monitor ESR procedures. Sed-Chek 2 employs a unique cell stabilizing process which mimics the rouleaux formation of patient samples.
Use of the Sed-Chek 2 ESR control will monitor technique as well as the environmental and physical factors which adversely affect ESR results. Improved laboratory confidence in accurate results is now assured by the use of the Sed-Chek 2 control.

Product Benefits

  • Superior product performance.
  • Greatest stability of any ESR control - 18 months from date of manufacture.
  • 31 day open vial stability.
  • Room temperature storage.
  • Easy to mix formula.
  • Run like a patient sample - no voiding of diluent required.
  • Bi-level control that monitors drifts and trends in patient results due to environmental and procedural factors.
  • QC program with Peer Group Review available at no extra charge.

Specifications

  • Cap Type Automatic self-zeroing.
  • Compatible Methods Both automated and manual ESR methods.
  • For Use With (Application) Whole Blood reference control material designed to monitor ESR procedures.
  • Packaging Vial.
  • Shelf Life 18 Months.
  • Stability 31 Days Open Vial.
  • Storage Requirements 20 to 22C.